hi all,

i have recently started to use an iCycler for setting up my real-time pcr systems and have encountered problems when trying to run a serial dilution of a template to evaluate my reaction efficiency.

what happens is, i'll make up for example 5 dilutions (1/10, 1/100, 1/1000 etc) of my template but the Ct values which i obtain at the end of the reaction never seem to match (i.e. the 1/1000 sample has the same Ct value as the neat template)... usually 2 or 3 of the samples will have differences in their Ct values which you would expect to see, but it never goes totally to plan.

am i suffering from contamination? poor pipetting? bad primers? (the melt curves are fine)

if anyone has a protocol i can follow i'd be grateful, details of the reagents i use to follow

regards

james brown


i use an iCycler with Abgene's SYBR Green Master Mix with Fluorescein in a 25ul volume, 2.5ul template, 70nM final primer concentration

-flashboy-

Just had a similar experience, the standard curve looked great till I got to the final two dilutions which gave me the same Ct value. Afraid I don't have any advice on how to fix it except to start all over and hope for the best.

-Fiona-

does anyone know if using a ten-fold serial dilution is the best idea??? the Ct values are all quite low so shall i try to use more template or maybe a series of 3-fold dilutions???


again any help is very much appreciated!!

[ to test my [pipetting i'm goping to run 10 wells of the same sample next week ]

-flashboy-

We only do 3 fold serial dilution when performing the standard curve. We usually do this do measure our primer efficiency. I think you are simply having a problem with scale. Sounds like the dilutions are the far end (high cT) are just to small to register a difference in cT. We use five 3 fold dilutions values. They are shown below:

150 ng
50 ng
16.67 ng
5.55 ng
1.85 ng

Of course if you are looking for copy number, these values may not be accurate for your application. However, if you are just measuring primer efficiency this numbers will work just fine.

Greg

-UnknownG-


上一篇:QRT-PCR result analysis-Real-Time PCR   下一篇:竞争定量PCR


↑返回顶部   打印本页   关闭窗口↓  
用户名: 新注册) 密码: 匿名评论 [所有评论]
评论内容:(不能超过250字,需审核后才会公布,请自觉遵守互联网相关政策法规。
 §最新评论:
 推荐文章
·菌落原位杂交(colony in situ h
 
 热点文章
·Rt-PCR实验步骤
·推荐:PCR实验技术指南
·影响PCR的主要因素
·PCR引物设计及软件使用技
·PCR反应体系
·实时荧光定量PCR原理
·琼脂糖凝胶电泳回收PCR产
·聚合酶链反应[PCR]
 
 相关文章
·QRT-PCR result analysis-
·竞争定量PCR
·Which housekeeping genes
·real-time PCR 常用探针和
·第一章 PCR和RT-PCR基础
·TaqMan PCR以及ABI-7700的
·第二章 增加RT-PCR灵敏度
·Equipment And Reagents F
 
鄂ICP备06020023号